The Diagnostic Routines allow the system user to checkout the system with minimum action. These routines are used during problem determination to determine if the system hardware has a problem and provide a Service Request Number (SRN) for the service organization. The Diagnostic Routines run more extensive tests on the adapters and options than the POST programs. The checkout options displayed are from the configuration record on the fixed disk. If the configuration record on the fixed disk does not match the installed features list, the program displays the TEST OPTION or the DIAGNOSTIC TEST LIST. TEST OPTION
DIAGNOSTIC TEST LIST
To Run the Diagnostic Routines: 1. Press ENTER after reading the DIAGNOSTIC OPERATING INSTRUCTIONS. 2. Choose Diagnostic Routines on the FUNCTION SELECTION menu. 3. Choose a checkout option on the DIAGNOSTIC SELECTION menu.
Diagnostic Routine Options and Functions System Checkout - Checks all installed features as far as possible without special actions. Keyboard Checkout - Checks keyboard adapter and keyboard. Display Checkout - Checks display
adapter and attatched display. Display Checkout displays
Diskette Drive Checkout - Checks
the diskette adapter and disk drive. A formatted blank
Fixed-Disk Drive and Media Checkout -
Checks all fixed-disk drives installed in the system
Other Checkout Options - Checks
the adapters and devices installed in the system unit. Your
|