Symptom / Error |
FRU / Action |
0010 0203
Not further explained |
1. System Board |
0011 0100
Serial connector error, possible system board failure |
1. Run Advanced Diagnostics |
0011 01XX / 0011 0200
0011 0600 / 0011 0800
0011 0900 |
1. System Board
2. Any Serial Device |
0011 02XX
Card selected feedback error |
1. Run Advanced Diagnostics |
0011 03XX
Port fails register check |
1. Run Advanced Diagnostics
2. System Board |
0011 06XX
Serial option cannot be turned off |
1. Run Advanced Diagnostics
2. System Board |
0011 07XX |
1. Serial Device Cable
2. System Board |
0011 10XX
Register test failed |
1. Run Advanced Diagnostics
2. System Board |
0011 16XX
16550 interrupt error |
1. Run Advanced Diagnostics |
0011 17XX
Failed baud rate test |
1. Run Advanced Diagnostics |
0011 XXXX
not listed above
(See 'Power Supply Voltage Check' before
replacing system board) |
1. System Board
2. Power Supply |
0012 01XX
Second Serial Adapter. Check voltages |
1. System Board
2. Any Serial Device |
0012 02XX / 0012 06XX
0012 08XX / 0012 09XX
0012 XXXX |
1. Dual Async Adapter /A
2. System Board
3. Any Serial Device |
0012 07XX |
1. Communications Cable
2. Dual Async Adapter /A |
0012 9020
Disk cache error |
1. Cached Processor Option
2. System Board |
0013 01XX / 0013 02XX |
1. Game Adapter
2. Joystick |
0014 02XX
Printer not ready |
Information only |
0014 03XX
No paper error, or interrupt failure |
Information only |
0014 04XX
System board timeout failure |
1. Run Advanced Diagnostics |
0014 05XX
Parallel adapter error |
1. Run Advanced Diagnostics |
0014 06XX
Presence test error |
1. Run Advanced Diagnostics |
0014 XXXX
not listed above
Check printer before replacing system board |
1. Printer
2. System Board |