int 17

lup.gif ldown.gif Interrups Categories Contents

rbline.gif

Int 17/DX=0ABCh - PRINTER - LPTx v5.x INSTALLATION CHECK
Int 17/DX=0B90h - PRINTER - LPTx v6.x INSTALLATION CHECK
Int 17/DX=0B91h - PRINTER - LPTx v7.x INSTALLATION CHECK
Int 17/DX=0F5Fh - PRINTER - LPTx v4.x INSTALLATION CHECK
Int 17/AH=00h - PRINTER - WRITE CHARACTER
Int 17/AH=01h - PRINTER - INITIALIZE PORT
Int 17/AH=02h - PRINTER - GET STATUS
Int 17/AH=02h/DX=0000h - INSET - INSTALLATION CHECK
Int 17/AX=0200h/BX=5050h - Enhanced Parallel Port (EPP) BIOS - INSTALLATION CHECK
Int 17/AH=03h - Emulaser ELTSR - INSTALL INTERRUPT HANDLERS
Int 17/AH=03h - IBM SurePath BIOS - Officially Private Function
Int 17/AH=03h - PC-MOS/386 v5.01 - PRINT SPOOLER - PRINT STRING
Int 17/AH=03h/BX=5A00h - DMP Print Spooler v2.03 - INSTALLATION CHECK
Int 17/AX=0300h - DOSISODE to WATTCP TSR Interface - socket
Int 17/AH=04h - Emulaser ELTSR - BEGIN CAPTURING OUTPUT
Int 17/AH=04h - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0400h - DOSISODE to WATTCP TSR Interface - bind
Int 17/AH=05h - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0500h - Emulaser ELTSR - ???
Int 17/AX=0500h - DOSISODE to WATTCP TSR Interface - connect
Int 17/AX=0501h - Emulaser ELTSR - UNHOOK INTERRUPTS
Int 17/AX=0502h - Emulaser ELTSR - SET ???
Int 17/AX=0503h - Emulaser ELTSR - DEACTIVATE???
Int 17/AH=06h - Emulaser ELTSR - ???
Int 17/AX=0600h - DOSISODE to WATTCP TSR Interface - listen
Int 17/AH=07h - Emulaser ELTSR - OPEN CAPTURE FILE
Int 17/AX=0700h - DOSISODE to WATTCP TSR Interface - accept
Int 17/AH=08h - Emulaser ELTSR - CLOSE CAPTURE FILE
Int 17/AX=0800h - DOSISODE to WATTCP TSR Interface - recvfrom
Int 17/AH=09h - Emulaser ELTSR - PRINT CAPTURE FILE???
Int 17/AX=0900h - DOSISODE to WATTCP TSR Interface - sendto
Int 17/AH=0Ah - Emulaser ELTSR - SET ??? FILENAME
Int 17/AX=0A00h - DOSISODE to WATTCP TSR Interface - select
Int 17/AH=0Bh - Emulaser ELTSR - GET ???
Int 17/AH=0Bh - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0B00h - DOSISODE to WATTCP TSR Interface - ioctl
Int 17/AH=0Ch - Emulaser ELTSR - SET ??? FLAG
Int 17/AH=0Ch - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0C00h - DOSISODE to WATTCP TSR Interface - close
Int 17/AH=0Dh - Emulaser ELTSR - GET TRUE ScrlLk STATE
Int 17/AH=0Dh - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0D00h - DOSISODE to WATTCP TSR Interface - shutdown - SHUTDOWN INTERFACE
Int 17/AH=0Eh - Emulaser ELTSR - BACKGROUND PROCESSING
Int 17/AH=0Eh - IBM SurePath BIOS - Officially Private Function
Int 17/AX=0E00h - DOSISODE to WATTCP TSR Interface - INSTALLATION CHECK
Int 17/AX=2000h - PC Paint Plus 2.0 - PRINTER DRIVER - INSTALLATION CHECK
Int 17/AX=2001h - PC Paint Plus 2.0 - PRINTER DRIVER - SET ??? FLAG
Int 17/AX=2002h - PC Paint Plus 2.0 - PRINTER DRIVER - GET INFORMATION
Int 17/AX=2003h - PC Paint Plus 2.0 - PRINTER DRIVER - ???
Int 17/AX=2004h - PC Paint Plus 2.0 - PRINTER DRIVER - GET ???
Int 17/AX=2005h - PC Paint Plus 2.0 - PRINTER DRIVER - ADVANCE PRINTER TO NEXT PAGE
Int 17/AX=2006h - PC Paint Plus 2.0 - PRINTER DRIVER - ADVANCE TO NEXT PAGE & SHUT DOWN
Int 17/AX=2007h - PC Paint Plus 2.0 - PRINTER DRIVER - UNIMPLEMENTED
Int 17/AX=2400h - Shamrock Software NET.24 v3.11+ - ENABLE/DISABLE API FUNCTIONS
Int 17/AX=2401h - Shamrock Software NET.24 v3.11+ - RECEIVE BLOCK, NO HANDSHAKE
Int 17/AX=2402h - Shamrock Software NET.24 v3.11+ - TRANSMIT BLOCK, NO HANDSHAKE
Int 17/AX=2403h - Shamrock Software NET.24 v3.11+ - GET STATUS AND TRANSMISSION BUFFER
Int 17/AX=2404h - Shamrock Software NET.24 v3.11+ - SEND ACK BLOCK
Int 17/AX=2405h - Shamrock Software NET.24 v3.11+ - SEND NAK BLOCK
Int 17/AX=2406h - Shamrock Software NET.24 v3.11+ - PREPARE CHARACTER-ORIENTED RECEIVE
Int 17/AX=2407h - Shamrock Software NET.24 v3.11+ - RECEIVE CHARACTER FROM REMOTE
Int 17/AX=2408h - Shamrock Software NET.24 v3.11+ - RECEIVE BLOCK, WITH HANDSHAKE
Int 17/AX=2409h - Shamrock Software NET.24 v3.11+ - TRANSMIT COMMAND, WITH HANDSHAKE
Int 17/AX=240Ah - Shamrock Software NET.24 v3.11+ - PREPARE CHARACTER-ORIENTED TRANSMIT
Int 17/AX=240Bh - Shamrock Software NET.24 v3.11+ - TRANSMIT SINGLE CHARACTER TO REMOTE
Int 17/AX=240Ch - Shamrock Software NET.24 v3.11+ - END CHARACTER-ORIENTED TRANSMIT
Int 17/AX=4B00h - Brother P-Touch - INSTALLATION CHECK
Int 17/AX=4B01h - Brother P-Touch - UNINSTALL
Int 17/AX=5000h - AX (Japanese AT) PRINTER - SET PRINTER COUNTRY CODE
Int 17/AX=5001h - AX (Japanese AT) PRINTER - GET PRINTER COUNTRY CODE
Int 17/AH=51h - AX (Japanese AT) PRINTER - JIS to Shift-JIS CONVERSION
Int 17/AH=52h - AX (Japanese AT) PRINTER - Shift-JIS to JIS CONVERSION
Int 17/AX=5555h/BX=AAAAh - LR - SET CONFIGURATION
Int 17/AX=5555h/BX=BBBBh - LR - GET CONFIGURATION
Int 17/AH=60h - FLASHUP.COM - INSTALLATION CHECK
Int 17/AH=61h - SPEEDSCR.COM - INSTALLATION CHECK
Int 17/AH=62h - T2PS v1.0 - UNINSTALL
Int 17/AH=63h - T2PS v1.0 - SET PARAMETERS
Int 17/AH=64h - T2PS v1.0 - GET PARAMETERS
Int 17/AX=6F00h/BX=0000h - HP Vectra - EXTENDED BIOS - F17_INQUIRE - INSTALLATION CHECK
Int 17/AX=6F02h - HP Vectra - EXTENDED BIOS - F17_PUT_BUFFER - PRINT BUFFER
Int 17/AH=80h - IBM SurePath BIOS - Officially Private Function
Int 17/AH=81h - Alloy NTNX, MW386 - CANCEL JOBS FOR CURRENT USER
Int 17/AH=82h - Alloy NTNX, MW386 - CANCEL ALL JOBS FOR CURRENT USER
Int 17/AH=83h - Alloy NTNX, MW386 - SET NUMBER OF COPIES
Int 17/AH=84h - Alloy NTNX, MW386 - GENERATE PRINT BREAK
Int 17/AH=84h - AX (Japanese AT) PRINTER - OUTPUT CHARACTER WITHOUT CONVERSION
Int 17/AH=85h - AX (Japanese AT) PRINTER - ENABLE/DISABLE CHARACTER CONVERSION
Int 17/AH=87h - Alloy NTNX - SET INDOS POINTER
Int 17/AH=88h - Alloy NTNX, MW386 - REMOVE PRINTER FROM SPOOLER
Int 17/AH=89h - Alloy NTNX, MW386 - ADD PRINTER TO SPOOLER
Int 17/AH=8Ah - Alloy NTNX - ACTIVATE USER-WRITTEN PRINTER DRIVER
Int 17/AH=8Bh - Alloy MW386 - GET PHYSICAL DEVICE NUMBER FROM NAME
Int 17/AH=8Ch - Alloy MW386 - GET DEVICE NAME FROM PHYSICAL DEVICE NUMBER
Int 17/AH=8Dh - Alloy NTNX,MW386 - RESET SPOOLER
Int 17/AH=8Eh - Alloy NTNX - GET INT 28 ENTRY POINT
Int 17/AH=8Fh - Alloy NTNX - GET DOS INTERCEPT ENTRY POINT
Int 17/AH=90h - Alloy NTNX, MW386 - SPOOL FILE BY NAME
Int 17/AH=91h - Alloy NTNX, MW386 - GET USER NUMBER AND CURRENT PRINTER
Int 17/AH=92h - Alloy NTNX - CHECK PRINTER DRIVER
Int 17/AH=94h - Alloy NTNX, MW386 - SELECT PRINTER
Int 17/AH=95h - Alloy NTNX, MW386 - GET CURRENT PRINTER
Int 17/AH=96h - Alloy NTNX - SET SERIAL PORT PARAMETERS
Int 17/AH=97h - Alloy NTNX, MW386 - SET DATA DRIVEN PRINT BREAK
Int 17/AH=98h - Alloy NTNX,MW386 - RESTART PRINTER
Int 17/AH=99h - Alloy NTNX, MW386 - GET/SET PRINTER MODE
Int 17/AH=9Ah - Alloy NTNX,MW386 - SET TAB EXPANSION
Int 17/AH=9Bh - Alloy NTNX,MW386 - SET PRINT BREAK TIMEOUT
Int 17/AH=A0h - Alloy MW386 - SPOOL COPY OF FILE
Int 17/AH=A4h - Alloy MW386 - ENABLE/DISABLE FORM FEED
Int 17/AH=A6h - Alloy MW386 - ENABLE/DISABLE BANNER PAGE
Int 17/AH=A7h - Alloy MW386 v2+ - GET/SET SPOOL FLAGS
Int 17/AH=A8h - Alloy MW386 - DEFINE TEMPORARY FILENAME
Int 17/AH=A9h - Alloy MW386 - CHANGE TEMPORARY SPOOL DRIVE
Int 17/AH=AAh - Alloy MW386 v2+ - GET REAL-TIME PRINTER STATUS
Int 17/AH=AFh - Alloy MW386 - CHECK SPOOLER
Int 17/AH=C0h - PC Magazine PCSpool - GET CONTROL BLOCK ADDRESS
Int 17/AH=C1h - PC Magazine PCSpool - BUILD PAUSE CONTROL RECORD
Int 17/AH=C2h - PC Magazine PCSpool - FLUSH PENDING WRITES
Int 17/AH=C3h - PC Magazine PCSpool - CANCEL PRINTER QUEUE (FLUSH ALL QUEUED OUTPUT)
Int 17/AH=C4h - PC Magazine PCSpool - QUERY SPOOLER ACTIVE
Int 17/AH=C5h - PC Magazine PCSpool - JOB SKIP PRINTER QUEUE
Int 17/AH=C6h - PC Magazine PCSpool - CHECK PRINTER QUEUE STATUS
Int 17/AH=C7h - PC Magazine PCSpool - CLOSE QUEUE
Int 17/AX=CD00h - INSET - EXECUTE COMMAND STRING
Int 17/AX=CD01h - INSET - GET IMAGE SIZE
Int 17/AX=CD02h - INSET - INITIALIZE
Int 17/AX=CD03h - INSET - EXECUTE INSET MENU WITHIN OVERRIDE MODE
Int 17/AX=CD04h - INSET - INITIALIZE LINKED MODE
Int 17/AX=CD05h - INSET - START MERGING IMAGE INTO TEXT
Int 17/AX=CD06h - INSET - GRAPHICS LINE FEED
Int 17/AX=CD07h - INSET - FLUSH GRAPHICS FROM MERGE BUFFER
Int 17/AX=CD08h - INSET - CANCEL LINK MODE
Int 17/AX=CD09h - INSET - ALTER TEXT LINE SPACING
Int 17/AX=CD0Ah - INSET - GET SETUP
Int 17/AX=CD0Bh - INSET - START GETTING SCALED IMAGE
Int 17/AX=CD0Ch - INSET - GET NEXT IMAGE STRIP
Int 17/AH=E0h - EPP BIOS - INSTALLATION CHECK
Int 17/AH=E1h - EPP BIOS - DISABLE EPP
Int 17/AH=E2h - EPP BIOS - ENABLE EPP
Int 17/AH=F0h - NorthNet Jetstream API - INSTALLATION CHECK
Int 17/AH=F1h - NorthNet Jetstream API - PRINT DATA BUFFER
Int 17/AH=F2h - NorthNet Jetstream API - GET PRINT PROGRESS STATUS
Int 17/AH=F3h - NorthNet Jetstream API - ABORT PRINT OPERATION
Int 17/AH=F4h - NorthNet Jetstream API - SET COMPLETION (POST) ADDRESS
Int 17/AH=F5h - NorthNet Jetstream API - PRINT DATA BUFFER FROM EXTENDED MEMORY
Int 17/AH=FFh/BX=0000h - PC-MOS/386 v5.01 - PRINT SPOOLER - CLOSE SPOOL FILE

rbline.gif

lup.gif ldown.gif Interrups Categories Contents