8554 Numeric Error Codes
Symptom/Error FRU/Action
00010200, 00010300,
00010400, 00010700
1. System Board
00010800  1. System Board
2. Communications Cartridge
00011000
(See “Memory Checkout” on page 115 before replacing any FRUs.)
1. IC DRAM Card or Memory Module
2. System Board
000110XX  1. IC DRAM Card or Memory Module
2. System Board
000113XX  1. System Board
2. Communications Cartridge
3. Any Drive
000114XX  1. Communications Cartridge
000118XX  1. IC DRAM Card or Memory Module
2. System Board
00016100  1. See “Testing the Backup Battery”
2. System Board
3. Voltage Converter
00016300, 00016400,
00016500, 00016900
(If setting configuration does not solve the problem, see “Checking Installed Devices” on page 131.)
1. Set Configuration
2. System Board
3. Communications Cartridge
4. Hard Disk Drive
5. IC DRAM Card
6. Memory Module
000166XX  1. Communications Cartridge
000171XX  1. See “Testing the Backup Battery”
2. System Board
000172XX  1. System Board
00017300 r 1. See “Testing the Backup Battery”
2. System Board
3. Voltage Converte
00017400
(If Automatic Configuration does not solve the problem, run Advanced Diagnostics.)
1. Set Configuration
2. System Board
3. Math Coprocessor
00019000, 000191XX  1. System Board
00019200  1. Lid Switch
2. Keyboard Control Card
3. System Board
00019300  1. System Board
000199XX  1. System Board
0001XXXX
(not listed above)
1. System Board
2. Communications Cartridge
3. Indicator Card
0002XXXX
(See “Memory Checkout” on page 115 before replacing any FRUs.)
1. IC DRAM Card or Memory Module
2. System Board
00030100, 00030500  1. Keyboard Control Card
2. System Board
3. Keyboard or Numeric Keypad
00030200, 00030300,
00030400
1. System Board
2. Keyboard Control Card
3. Keyboard or Numeric Keypad
00030600  1. Keyboard or Numeric Keypad
2. Auxiliary Input Device
3. Keyboard Control Card
4. System Board
5. I/O Panel Assembly
0004XXXX  1. System Board
2. Any Parallel Device
3. Communication Cable
4. I/O Panel Assembly
000601XX  1. Diskette Drive
2. System Board
3. Diskette Drive Cable
000602XX  1. Defective Diskette
000655XX, 000662XX
000670XX to 000675XX
1. System Board
2. Diskette Drive
3. Diskette Drive Cable
0006XXXX
Unsupported drive or cable.
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
000720XX  1. System Board
2. Math Coprocessor
0007XXXX  1. Math Coprocessor
2. System Board
0011XX00  1. System Board
2. Serial Connector
3. Any Serial Device
4. Communication Cable
0014XXXX
(See “Printer Checkout” on page 468 before replacing any FRUs.)
1. Printer
2. System Board
0024XX00  1. Display Control Card
2. Voltage Converter
005002XX, 005006XX,
005008XX
1. Display Control Card
2. Voltage Converter
3. External Display
4. I/O Panel Assembly
005004XX, 005010XX,
005032XX
1. Display Control Card
2. LCD Panel
3. LCD Cable
005009XX  1. External Display
2. Display Control Card
3. I/O Panel Assembly
00860100, 00860200
00861700, 00861800
1. Mouse or Trackball
2. System Board
3. Numeric Keypad
4. I/O Panel Assembly
0086XX00  1. System Board
2. Mouse or Trackball
3. Numeric Keypad
4. I/O Panel Assembly
0101XXXX  1. See “Fax/Modem Checkout” on page  466.
010436XX  1. System Board
2. Hard Disk Drive
3. Hard Disk Drive Cable
0104XXXX  1. Hard Disk Drive
2. System Board
3. Hard Disk Drive Cable
0130XXXX  1. Indicator Card
2. System Board
3. Keyboard Control Card
0137XXXX  1. Serial Adapter
2. System Board
3. Communication Adapter Holder
4. Any Serial Device
5. Communication Cable
0166XXXX, 0167XXXX  1. Adapter in Communications Cartridge
2. Communications Cartridge
I9990301
(Startup drive not found.)
1. Start RefDisk and verify startup sequence
  a. Select Set features from the Main Menu.
  b. Select Set startup sequence.
  c. Check the list of devices on the screen.
I9990302
(Operating system not found.)
1. Make sure operating system is installed.
2. Hard Disk Drive
3. System Board
4. Hard Disk Drive Cable
I998XXXX, I9990303
(See “Hard Disk Partition” on page 132 before
replacing any FRUs.)
1. Restore system programs on system partition.
2. Set configuration
3. Hard Disk Drive
4. System Board
5. Hard Disk Drive Cable