Int 21/AH=E3h/SF=3Dh

lup.gif ldown.gif Interrups Categories Contents

rbline.gif

Novell NetWare - BINDERY SERVICES - READ PROPERTY VALUE

AH = E3h subfn 3Dh
DS:SI -> request buffer (see #01942)
ES:DI -> reply buffer (see #01943)

Return:
AL = status (see #01941)

Desc: Retrieve one 128-byte segment of the specified property's value

Note: This function is supported by Advanced NetWare 1.0+ and Alloy NTNX

See Also: AH=E3h/SF=39h - AH=E3h/SF=3Ch - AH=E3h/SF=3Eh -

(Table 01941) Values for NetWare function status: 00h successful 96h server out of memory E8h not item property ECh no such segment F0h wildcard not allowed F1h invalid bindery security level F8h not permitted to write property F9h not permitted to read property FBh no such property FCh no such object FEh server bindery locked FFh bindery failure

See Also: #01937 - #01946

Format of NetWare "Read Property Value" request buffer: Offset Size Description (Table 01942) 00h WORD length of following data (max 44h) 02h BYTE 3Dh (subfunction "Read Property Value") 03h WORD (big-endian) type of object 05h BYTE length of object's name (01h-2Fh) 06h N BYTEs object name. BYTE segment number (01h on first call, increment until done). BYTE length of property's name (01h-0Fh) N BYTEs property name

See Also: #01943 - #02188

Format of NetWare "Read Property Value" reply buffer: Offset Size Description (Table 01943) 00h WORD (call) 0082h (length of following results buffer) 02h 128 BYTEs property's value 82h BYTE more segments (00h no, FFh yes) 83h BYTE property's flags

See Also: #01942 - #02188

Category: Netware - Int 21h - N