Interrups | Categories | Contents |
AX = 0001h subfn 0005h DS:DX -> communications control block (see #03340)
Return:
AX = status (0000h-000Ah,00A2h,00A3h) (see #03339)
Desc: Returns results for all asynchronous operations invoked from the data segment used for this call
Range:
INT 60h to INT 66h
Notes: The Banyan interrupt handler is identified by the string "BANV" in the four bytes immediately preceding the interrupt handler
See Also: AX=0001h/SF=0002h - AX=0001h/SF=0009h
(Table 03339) Values for VINES function status: 0000h successful 0001h service not installed 0002h invalid service ID 0003h-000Ah reserved for BANV interface errors 00A2h no more buffer space available 00A3h timeout event
Format of VINES control block for subfunction 0005h: Offset Size Description (Table 03340) 00h WORD 0005h 02h WORD pointer to argument block (see #03341) 04h WORD error return code 06h 4 BYTEs reserved
See Also: #03337 - #03342
Format of VINES argument block for subfunction 0005h: Offset Size Description (Table 03341) 00h WORD pointer to WORD event pointer 02h WORD timeout in multiples of 200ms, FFFFh = infinite
See Also: #03338 - #03340
Category: Network - Int 61h - B